Setting Spray Counter Warning

The spray counter warning alerts the operator when the total spray counter reaches the warning setting. This function is typically used to schedule routine maintenance on the spray gun or other system components.

The spray counter warning is set from the Spray Monitor Configuration screen.

For the warning to function, it must be enabled.

NOTE: If your system uses the new Spray Monitor module, part 1065268, the total spray and bad spray counters are automatically saved in the Spray Monitor's nonvolatile memory. If power to the Spray Monitor is turned off, the counter data is saved. If your system uses the old-style Spray Monitor modules, part 1042409, the spray counters are automatically reset to zero when the spray monitor is turned off.

  1. Icon_TOOLSGREEN.JPG Touch the information and setup bar on the appropriate Spray Monitor faceplate.

  2. Icon_SM.jpg Select Spray Monitor Configuration from the drop-down menu.

  3. Icon_Details.jpg Touch the Information button at the top of the Spray Monitor Configuration window.

  1. Icon_RESET_BUTTON.JPG Touch this button below the spray counter warning icon SPRAY_COUNTER_WARNING_ICON.JPG. The counter setting screen appears.

  2. Use the numeric keypad to enter the desired count in the bottom field. The top field displays the previous setting.

  3. Icon_OK.jpg Accept the setting, or
    Icon_Cancel.jpg cancel the setting.

  1. To use the warning, go to the Fault screen and enable it.