Create Spray Machines as desired.
Enable One-Button Recipes.
Touch
the On-Button Recipe button on the main button bar and select [Setup] from the drop-down
menu. The
One-Button
Recipe Setup window opens. Existing recipes are listed in the
Line Recipe field.
Touch
this button below the Line Recipe field to open the Add
New Recipe window.
Enter a line recipe name, using the Windows on-screen keyboard if your
PC does not have one.
This name will appear in the One-Button Recipe drop-down menu. Close
the window when done.
The new line recipe name now appears in the line recipe field and is
selected (reverse highlighted).
If you want the recipe instructions to be displayed when the recipe is loaded, check the Show Instruction on Download box.
Touch
this button to enter a Line Recipe Number. If you have an optional
Anybus module installed, this number can be output when the recipe
is being used to a customer-supplied controller or other device for
monitoring or control functions.
Enter the number of seconds for the Base Alarm Delay. The delay timer starts when a new recipe starts loading into the modules. The Base Pressure alarms are shut off during the delay, to prevent nuisance alarms should the base pressure change before new alarm settings are loaded.
Touch
this button to open the Line Recipe Instructions
window. Enter instructions for the operator for settings and adjustments
that must be manually performed before beginning production. Use the
Windows on-screen keyboard if the iTrax PC does not have one.
Print a copy of the instructions, if
desired.
Save
the instructions and close the window.
Touch
this button below the Spray Machine
field to open the Add
Machine window
Select one or more spray machines from the list. The spray machines
must be created first, through the System Configuration window.
Touch
this button.
The spray machines appear in the Spray Machine list and the modules associated with the currently selected spray machine appear in the Module list.
Make sure the desired One-Button Recipe is selected in the Line Recipe field.
Touch the Upload Recipes button under the Module list.
The current configurations of each module in the list are copied to the recipe. A recipe file is created for each module with a name such as 12 Ounce BeerSM1, which can be interpreted as 12 Ounce Beer Spray Monitor 1. When loaded, the module recipe name is displayed in the Recipe field on the Information tab of each module configuration window.
You can create a different One-Button Recipe for each product at one time, using the Nordson Default configuration settings for each module. Then Before beginning production of a product for the first time, you can load the recipe and then adjust each module's configuration as necessary while running trial production. The changes you make are automatically saved to the One-Button Recipe module recipes.
Once you have set up a One-Button Recipe for each product the spray machine can handle, you can simply load the One Button Recipe when product changes occur.