Fault Reset Mode

NOTE: Only Nordson service personnel can access this setting. Contact your Nordson representative if you need to change this setting.

A fault changes the state of the Spray Monitor relays and LEDs and turns on the OI fault indicators and fault messages. The alarm reset mode feature allows you to determine how alarms are reset (manually or automatically).

Manual mode: You must correct the alarm condition and reset the alarm to reset the relays and LEDs and turn off the OI alarm indicators.

Automatic mode: The relays are automatically reset after 5 milliseconds. The LEDs, OI indicators, and alarm status messages stay on until the alarm condition is corrected and the alarm is manually cleared.

CAUTION: If you set the alarm reset mode to Automatic, use the Spray Monitor solid-state relay option. Refer to Spray Monitor manual for more information.

NOTE: If a Low Pressure Alarm occurs and the alarm reset mode is Automatic, the relay is activated (closed) and remains closed until the base pressure increases above the alarm setpoint.

Default Setting: Manual

  1. Icon_TOOLSGREEN.JPG Touch the information and setup bar on the appropriate Spray Monitor faceplate.

  2. Icon_SM.jpg Select Spray Monitor Configuration from the drop-down menu.

  3. Icon_SERVICE.JPG Touch the Service button at the top of the Spray Monitor Configuration window.

  1. Use the scroll bar at the right-hand side of the window to scroll down to the lower half of the window.

  2. Touch the Alarm Reset Mode button to set the mode to Manual or Automatic.