The OI will generate a fault if the gun is on for longer or shorter than the total trigger duration. The trigger fault range settings allow you to set short trigger and long trigger warning and alarm values to indicate if the guns are spraying too much or too little material.
NOTE: If you are using iTrax Spray Controllers, set the spray gun trigger duration (Spray Time) on the controller configuration screen. If you are using a different timer, refer to the timer manual to set the trigger duration.
Default Trigger Fault Range Settings
Touch the information and setup bar on the appropriate Spray Monitor faceplate.
Select Spray Monitor Configuration from the drop-down menu.
Touch the Trigger Timing button at the top of the Gun Configuration window.
Touch the On/Off buttons to enable or disable the warnings and alarms as desired.
Drag the slider or touch the – and + buttons to increase or decrease short or long trigger fault ranges.