Setting Fault Tolerances

Fault Tolerance settings determine the number of fault conditions that may occur in a set period of time before the OI alerts you to a fault condition. A value of 1 disables the tolerance function and causes a warning or alarm to be generated every time a fault condition exists. Having a value greater than 1 ensures that a transient, one-time fault condition does not cause an alarm and interrupt production.

Using the default settings as an example: If three warning conditions occur within three seconds, the OI will generate an warning. With the alarm tolerance set to 1, the OI will generate an alarm each time that an alarm condition occurs.

Default Settings

 

  1. Icon_TOOLSGREEN.JPG Touch the information and setup bar on the appropriate Spray Monitor faceplate.

  2. Icon_SM.jpg Select Spray Monitor Configuration from the drop-down menu.

  3. Icon_Fault_Timing.JPG Touch the Gun Timing button at the top of the Spray Monitor Configuration window.

  1. Drag the sliders or touch the and + buttons to increase or decrease the Fault Tolerance settings as appropriate.