Base pressure is the fluid pressure at the spray gun when it is not spraying. The base pressure fault settings allow you to set points at which an alarm or warning occurs when the base pressure goes above or below the calibrated base pressure. Depending on your application, you may enable or disable any combination of these warnings and alarms.
Touch the information and setup bar on the appropriate Spray Monitor faceplate.
Select Spray Monitor Configuration from the drop-down menu.
Touch the Base Pressure button at the top of the Spray Monitor Configuration window.
Touch the On/Off buttons to enable or disable the warnings and alarms as desired.
Drag the sliders or touch the – and + buttons to increase or decrease low or high base pressure limits.
Touch the OK button to accept your settings.
Calibrate the Spray Monitor.