During normal operation, the PRx Module fault LEDs remain off. If a fault occurs, the appropriate LED lights.
Use this procedure to turn on and off the LEDs to make sure they are functioning.
CAUTION: Shut off the coating system before testing the PRx Modules. Testing with the coating system operating will generate an alarm and shut down the system.
Touch
the information and setup bar on the appropriate PRx Module faceplate.
Select
PRx Configuration from the
drop-down menu.
Touch
the Diagnostics button at
the top of the PRx Configuration
window.
NOTE: To prevent an operator from accidentally tripping the relays and shutting down the coating system, you must turn on the diagnostics mode before you can use it.
Touch
the Test Mode button toggle
it ON. The switch backgrounds change from gray to green and the switches
move if necessary to show the current operating state of the LEDs.
The PRx Module is now in diagnostics mode.
Touch the switches as necessary to set the LEDs to the desired state. Switch Status
Touch the test button to test the LEDs. To return the LEDs to their
actual operating state, touch the button again.