NOTE: Only Nordson service personnel can access this setting. Contact your Nordson representative if you need to change this setting.
The Electrical Noise Warning is built into the Spray Monitor modules. The warning is generated if electrical noise in the pressure transducer or gun wiring is affecting the sampling of base and fire pressures.
If the Spray Monitor is used with a CleanSpray gun, this warning may generate false alarms. If this is a problem then this warning should be turned Off.
If the Spray Monitor is used with a MEG, A10A, or A20A lacquer gun, this warning should be turned On, as electrical noise could affect monitoring of base and fire pressures and hide problems leading to rejects.
Default Setting: On
Touch the information and setup bar on the appropriate Spray Monitor faceplate.
Select Spray Monitor Configuration from the drop-down menu.
Touch the Service button at the top of the Spray Monitor Configuration window.
Use the scroll bar at the right-hand side of the window to scroll down to the lower half of the window.
Touch the Electrical Noise Warning button to turn the warning On or Off.