All modules must have a unique network address setting (except when associating PRx modules with Spray Monitors). Care must be taken not to assign modules the same network address.
Module |
Start |
End |
Comment |
Spray Monitor |
01 |
63 |
Switch range is 00 to 99 (see Note A). |
PRx |
01 |
63 |
Associated with Spray Monitors (see Note B). |
PRx |
64 |
98 |
Not associated with Spray Monitors (see Note B). |
Spray Controller |
101 |
263 |
Switch range is 000 to 999 (see Note C). |
Note A: The factory default switch setting is 01. Valid switch settings for Spray Monitors are 01 through 63. Do not set to 00 or 64 through 98. Setting the switches to 99 and cycling power will restore the module to the factory default configuration.
Note B: The factory default switch setting is 01. Valid switch settings for PRx modules are 01 through 98.
Do not set to 00. Setting the switches to 99 and cycling power will restore the module to the factory default configuration. For normal pressure control applications, the PRx is associated with a Spray Monitor by setting the address switch settings to the same value for both Spray Monitor and PRx. The actual network address of a PRx module is 64 plus the address switch setting.
For example, a PRx module set to 01 is address 64 on the network and a PRx module set to 63 is address 127 on the network. Make sure the actual network address of the PRx module does not conflict with other modules. If a PRx module is not associated with a Spray Monitor, use switch settings 64 through 98. Note that if the module is set to 98, the actual network address is 162, which may conflict with a Spray Controller address.
Note C: The factory default switch setting is 100. Valid switch settings for Spray Controllers are 001 through 511. For compatibility issues, do not set the address to 000 through 099 and 264 through 998. Setting the switches to 999 and cycling power will restore the module to the factory default configuration.
Module |
Start |
End |
Comment |
Spray Monitor |
01 |
10 |
Start with gun as address 01. |
PRx |
01 |
10 |
Pair with Spray Monitors. |
PRx |
64 |
65 |
Not associated with Spray Monitors. |
Spray Controller |
101 |
110 |
Makes it easy to associate with gun (Spray Monitor). |
This example would accommodate a typical spray line having 5 spray machines with 2 guns per machine and have 32 modules on the network excluding the CAN to USB Adapter. For systems larger than this, it is recommended that a separate computer and network be used.