Warning: Electrical/Mechanical Noise

Electrical or mechanical noise in the spray system is affecting the iTrax Spray Monitor.

Possible Cause

Resolution

Pressure transducer malfunction

Check the pressure transducer wiring. Make sure the twisted pair wiring is connected properly. Check for correct voltage on the excitation circuit. Replace the pressure transducer if necessary.

Electrical connections shorted, loose, or incorrect; interference from other power sources or wires

Check all iTrax system electrical connections. Check and relocate possible sources of interference.

Fluid supply system

Make sure vibrations in the fluid supply system are dampened. Minimize pressure fluctuations.