The Can-In-Pocket (CIP) feature uses a proximity sensor to verify that a can has fallen into the spray pocket before the spray gun fires. CIP allows the spray monitor to verify that a timer signal is received for every can that is detected. (This feature must be used with a proximity sensor and the new iTrax Spray Monitor module, part 1065268)
When CIP is used, the Spray Monitor must receive both a timer and CIP signal each time a can is detected and a gun fires. If either the CIP or timer signal is not received, the Operator Interface displays a fault.
One CIP proximity sensor is mounted in each spray pocket and is wired to the CIP inputs on the left side of the Spray Monitor module.
NOTE: This function must be enabled by your Nordson Service Representative.