Error Code |
Message |
Cause/Correction |
101 |
CAN bus fault detected |
Hardware error. Check the CAN cable for shorts. If the cable is good, replace the PC104 CAN card. |
102 |
CAN receive buffer overflow |
Host CAN interface received too much data and could not process it quickly enough. Reboot the system. |
103 |
Message timeout |
Remote CAN device did not respond to a direct request in the allotted time. Check the gun card or iFlow card. |
104 |
Went offline |
Normal operational message. The user will see this message if the booth exhaust fan is shut off, which removes power from gun cards, or if the gun card is disconnected, or if the iFlow module is disconnected from the CAN network. |
105 |
Returned to online |
Normal operational message. No action required. |
107 |
Communications errors |
These error messages indicate that communications on the iControl CAN bus may be having problems. Troubleshooting should include verification of all CAN cable connections and grounding, and gun cable connections and continuity. CAN errors can also be caused by individual gun cards or the iControl PC to PC104 card interface. These errors do not indicate a specific device failure as all devices are in parallel on the CAN bus. |
108 |
||
109 |
||
110 |
||
111 |
||
112 |
||
113 |